型号
|
框体尺寸(高*宽*厚)
|
额定制冷量
|
额定制热量
|
地暖制热量
|
室外机额定功率
|
电源
|
|
|
|
|
|
空调制冷
|
EER
|
空调制热
|
制热COP
|
地暖功率
|
地暖COP
|
|
|
mm
|
kW
|
kW
|
kW
|
kW
|
kW/kW
|
kW
|
kW/kW
|
kW
|
kW/kW
|
|
YUOM030
HSEACQ
|
840×1100×390
|
8
|
9.5
|
12
|
2
|
4
|
2.3
|
4.13
|
2.7
|
4.44
|
220V~50Hz
|
YUOM035
HSEACQ
|
10
|
11.2
|
12
|
2.6
|
3.85
|
2.7
|
4.14
|
2.7
|
4.44
|
YUOM045
HSEACQ
|
12.5
|
14
|
14
|
3.54
|
3.53
|
3.3
|
4.24
|
3.2
|
4.38
|
YUOM050
HSEACQ
|
14
|
16
|
16
|
4.15
|
3.37
|
4.3
|
3.72
|
3.9
|
4.1
|
YUOM060
HSEACQ
|
15.5
|
17
|
17
|
5.13
|
3.02
|
4.83
|
3.52
|
4.5
|
3.78
|
YUOM065
HSEACQ
|
1380x950x320
|
18
|
20
|
20
|
4.75
|
3.79
|
4.7
|
4.26
|
4.7
|
4.26
|
YUOM070
HSEACQ
|
20
|
22.4
|
22.4
|
5.3
|
3.77
|
5.3
|
4.23
|
5.5
|
4.07
|
YUOM080
HSEACQ
|
22.4
|
24
|
25
|
6
|
3.73
|
5.85
|
4.14
|
6.4
|
3.91
|
YUOM090
HSEEAQ
|
1650×1100×390
|
24.5
|
26
|
26
|
6.8
|
3.6
|
6.4
|
4.06
|
6.2
|
4.19
|
380V~3N 50Hz
|
YUOM100
HSEEAQ
|
28
|
31.5
|
31.5
|
7.35
|
3.9
|
8.2
|
3.82
|
7.6
|
4.42
|
YUOM120
HSEEAQ
|
32
|
34
|
34
|
8.9
|
3.72
|
9.4
|
3.62
|
8.4
|
4.05
|
注:1、额定制冷量测试工况:室内温度:27℃DB,19℃WB 室外温度:35℃DB 管道长度:7 . 5m, 管 道 高 度 差 : 0m
额定制热量测试工况:室内温度:20℃DB 室外温度:7℃DB,6℃WB 管道长度:7 .5m, 管道高度差:0m
" 2、上表中噪音数值是在无反射回声的消音室内测得。在实际安装情况下,受环境噪音及反射回声影响,一般高于此数值。
3、该系列室外机可连接约克YDCK018~160H0NAGQ1系列室内机"
型号
|
框体尺寸(高*宽*厚)
|
额定制冷量
|
额定制热量
|
地暖制热量
|
制冷功率
|
EER
|
制热功率
|
空调COP
|
地暖功率
|
地暖COP
|
电源
|
|
mm
|
kW
|
kW
|
kW
|
kW
|
kW/kW
|
kW
|
kW/kW
|
kW
|
kW/kW
|
|
YUOM035
HSEAAQ
|
1250×950×320
|
10
|
11.2
|
11.2
|
2.5
|
4
|
2.63
|
4.26
|
2.53
|
4.43
|
220V~50Hz
|
YUOM045
HSEAAQ
|
12.5
|
14
|
14
|
3.35
|
3.73
|
3.4
|
4.12
|
3.22
|
4.35
|
YUOM050
HSEAAQ
|
14
|
16
|
16
|
3.99
|
3.57
|
3.95
|
4.05
|
3.58
|
4.47
|
YUOM060
HSEABQ
|
15.5
|
17
|
17
|
4.6
|
3.37
|
4.3
|
3.95
|
4.2
|
4.05
|
YUOM060
HSEAAQ
|
1650×950×320
|
15.5
|
18
|
18
|
4.43
|
3.5
|
4.4
|
4.09
|
4.15
|
4.34
|
YUOM065
HSEAAQ
|
18
|
20
|
20
|
5.1
|
3.53
|
5
|
4
|
4.8
|
4.17
|
YUOM070
HSEAAQ
|
20
|
22.4
|
22.4
|
5.69
|
3.51
|
5.6
|
4
|
5.4
|
4.15
|
注:1、额定制冷量测试工况:室内温度:27℃DB,19℃WB室外温度:35℃DB管道长度:7.5m,管道高度差:0m
额定制热量测试工况:室内温度:20℃DB 室外温度:7℃DB,6℃WB 管道长度:7 .5m, 管道高度差:0m
" 2、上表中噪音数值是在无反射回声的消音室内测得。在实际安装情况下,受环境噪音及反射回声影响,一般高于此数值。
3、该系列室外机可连接约克YDCK018~160H0NAGQ1系列室内机"